تفاصيل الوثيقة

نوع الوثيقة : مقال في مجلة دورية 
عنوان الوثيقة :
Evaluation of HER-2/neu gene amplification by fluorescence in situ hybridization and immunohistochemistry in saudi female breast cancer
Evaluation of HER-2/neu gene amplification by fluorescence in situ hybridization and immunohistochemistry in saudi female breast cancer
 
الموضوع : علم الأمراض 
لغة الوثيقة : الانجليزية 
المستخلص : BACKGROUND: Amplification of the HER-2/neu oncogene and concomitant over-expression of its protein are detected in approximately 18% of invasive ductal carcinoma of the breast and is associated with poor prognosis. This study tested the use of fluorescence in situ hybridization (FISH) and immunohistochemistry (IHC) to evaluate the HER-2/neu gene status and to ascertain the concordance rate between the two methods. PATIENTS AND METHODS: Eighty two tumour samples containing representative tumour were divided for testing using each assay. HER-2/neu gene amplification is scored as a ratio of HER-2/neu gene amplification to chromosome 17. The ratio should be >2.2 to be considered as positive. 20 cells should be counted and an average score taken. An extra 20 cells should be counted if the ratio is between 1.8-2.2. RESULTS: Seventy five effective samples were used. HER-2/neu gene was amplified in 19 out of 75 cases (25%) whereas, HER-2 protein, by IHC was over-expressed in 18 out of 75 cases (24%). In the 44 negative cases by IHC analysis only 7 cases (16%) of them showed amplification by FISH. Three out of 13 cases (23 %) scored as +2 showed gene amplification by FISH while 9 cases out of 18 cases (50%) were scored as +3. High concordance with FISH results 37:44 (84 %) was noted in negative cases (0/+1 cases), while lower concordance 3:13 (23 %) was seen in +2 cases. CONCLUSION: This study revealed a significant concordance between FISH results and IHC results. The study also showed that HER2/neu amplification is higher in Saudi patients than other western populations. However, due to the inherent failures of the IHC assay, FISH should always be used when the IHC results are inconclusive. The rational algorithm for HER-2/neu testing would be to perform IHC first, followed by FISH to validate equivocal IHC results 
ردمد : 0250-7005 
اسم الدورية : Anticancer Research 
المجلد : 30 
العدد : 10 
سنة النشر : 1431 هـ
2010 م
 
نوع المقالة : مقالة علمية 
تاريخ الاضافة على الموقع : Sunday, August 14, 2011 

الباحثون

اسم الباحث (عربي)اسم الباحث (انجليزي)نوع الباحثالمرتبة العلميةالبريد الالكتروني
جودة المغربيAl-Maghrabi, Jaudah باحث مشاركدكتوراه 

الملفات

اسم الملفالنوعالوصف
 30237.pdf pdf 

الرجوع إلى صفحة الأبحاث